沼气发电机组维护要注意哪些故障产生?

发布时间:2024-03-16 发布人:中拓 发布来源:/

一、沼气发电机组的启动注意事项

1、 Precautions for starting biogas generator sets

1、先检查:循环水,润滑油,气路。

1. First check: circulating water, lubricating oil, and air circuit.

2、打开气路开关,扭开电瓶钥匙(打开电磁阀开关,确定转速控制开关处于怠速状态)按下启动开关。

2. Turn on the gas circuit switch, turn on the battery key (turn on the solenoid valve switch, make sure the speed control switch is in idle state), and press the start switch.

3、沼气发电机组启动后,先怠速运转,等到水温和油温升高,大约45度左右。将转速开关拨额定转速。

3. After starting the biogas generator set, idle it first and wait for the water temperature and oil temperature to rise, about 45 degrees. Turn the speed switch to the rated speed.

4、沼气发电机组按额定转速运转几分钟,合上发电机端高压电输出开关。机组正常发电。

4. The biogas generator set is operated at the rated speed for a few minutes, and the high-voltage output switch at the generator end is closed. The unit generates electricity normally.

后需要注意,沼气发电机组维护:300小时,更换一次机油,每月更换空滤机油滤。长期不用要每隔一段时间启动一次,每次运转半小时。希望以上的介绍能给用户带来帮助。

Attention should be paid to the maintenance of the biogas generator set: 300 hours, replace the oil once, and replace the air filter and oil filter every month. If not in use for a long time, it should be started every other period of time and run for half an hour each time. I hope the above introduction can be helpful to users.

20231114103601159.jpg

二、沼气发电机组出现不能启动的现象怎么办?

2、 What should be done if the biogas generator unit fails to start?

1、电瓶电量不足检查电瓶充电量。

1. Check the battery charging capacity when the battery is low.

2、电瓶线及插头松动。

2. The battery cable and plug are loose.

3、火花塞点不了火。建议更换火花塞,因为火花塞是易耗品,

3. The spark plug cannot ignite. Suggest replacing spark plugs as they are consumables,

4、燃气管道堵塞

4. Gas pipeline blockage

时间久了,阻火器那里囤积大量水,燃气通不了。或者在北方的冬天,里面结冰了。

Over time, a large amount of water has accumulated in the flame arrester, and gas cannot be supplied. Or in winter in the north, it freezes inside.

5、沼气里甲烷成份不稳定,或者甲烷浓度不够。

5. The methane composition in biogas is unstable or the methane concentration is insufficient.

6、电压板、调速板、执行器、速度传感器等回路故障。检查相应的设备及回路。

6. Voltage board, speed control board, actuator, speed sensor and other circuit faults. Check the corresponding equipment and circuits.